CNBuiltrue Applications

Applications

These four applications account for most of the valves we ship. Each one fails in a different way, so the valve specification has to follow the duty — not the other way round.

District Heating

Primary and secondary networks, heat exchange stations and long-distance transmission mains. Valves here sit on lines that run hot for most of the year and shut down rarely. The governing question is not whether the valve opens, but whether it still seals tight after several heating seasons.

A fully welded body removes the body joint, which is the usual leak path on a flanged valve. What remains is the seat and the stem seal — both replaceable without cutting the line on our welded designs.

Typical selection: Q361F worm gear floating valve on branch lines; Q367F trunnion valve on transmission mains where the valve has to open against high differential; GLQ61F strainer valve on networks with debris or first-fill contamination.

Power Plants

Branch isolation upstream of heat exchangers and auxiliary equipment, plus main lines in thermal and combined heat and power plants. Differential pressure at closing is the governing factor here, which is why trunnion-mounted valves are specified as line size grows — the ball is supported top and bottom, so operating torque stays manageable.

Typical selection: Q367F trunnion valve, DN150 to DN1400, with electric or pneumatic actuation where the valve is part of an automated sequence.

Industrial Piping

Steel works hot water lines, chemical and metallurgical process piping. The medium is often not clean water — steam, condensate and mildly aggressive fluids all appear. Material selection matters more here than on a heating network: body in 20# or A105, sphere in SS304, seat in PTFE or carbonised PTFE, stem in 20Cr13 or SS420.

Typical selection: Q41F and Q341F flanged valves where the line can be dismantled for maintenance; Q61F welded valves where it cannot.

Direct Burial

Buried mains where the operator sits above grade. The alternative is a valve well — a civil works item, a confined-space entry, and a permanent water-ingress problem. An extended-stem valve removes all three: the stem height is made to order from the pipe centre to the top, the worm gear opens upward with a fully waterproof structure, and no well is built.

Typical selection: ZMQ61/7F for DN50 to DN350; ZMQ361/7F for DN150 to DN1400.

Not sure which applies?

Send the line size, the pressure rating and whether the valve sits above or below grade. We will come back with the model and the drawing.

Request a valve quotation